CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1 and Type 2 DC surge protector
DDC30S-20-85
1-pole Type 1 and Type 2 SPD for 48 Vdc
DDC30S-20-85
Part Number
828110222
Combined SPD for DC supplies, 2-pole
Type 1 + 2
In: 15 kA / Imax: 30 kA
Iimp: 4kA
Pluggable module
Remote signaling
prIEC 61643-41 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DDC range is Type 1 + 2 pluggable surge protectors designed for equipment connected to DC powerlines. The technology based on high energy varistor equipped with thermal disconnection mechanism offers protection efficiency and and a maximal reliability.
Select another reference:
DDC30S-10-65
DDC30S-10-85
DDC30S-20-65
DDC30S-20-85
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Nominal DC voltage
Un-dc
75 Vdc
Max. AC operating voltage
Uc
60 Vac
Max. DC operating voltage
Uc
85 Vdc
Residual Current
Leakage current to Ground
Ipe
< 0.1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
30 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
4 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
8 kA
Connection mode(s)
+/PE and -/PE
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
390 V / 780 V
Admissible short-circuit current
Isccr
50 000 A
Network type
DC
Technology
MOV
SPD configuration
2-poles
Connection to Network
Srew terminals: 2.5-25mm² +/-: 1.5-10mm²
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Disconnection from DC network
Disconnection indicator
2 mechanical indicators - Red/Green
Spare module(s)
MDDC30-85
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 2TE (EN43880)
Standards compliance
prIEC 61643-41
Thermal disconnector
Internal
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
1-pole Type 1 and Type 2 SPD for 48 Vdc
Standards compliance:
prIEC 61643-41
Technology:
MOV
SPD configuration:
2-poles
Remote signaling of disconnection:
Output on changeover contact
SPD type :
1+2
Max. AC operating voltage :
60 Vac
Max. DC operating voltage:
85 Vdc
Residual Current :
< 0.1 mA
Max. discharge current :
30 kA
Impulse current by pole :
4 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DDC30S-20-85
Part Number:
828110222
Or equivalent
Read more
About CITEL
Read more