1-pair DIN rail plug-in Data surge protector

DLAWTS1-24D3/R
Part Number 6421034
DLAWTS1-24D3/R
  • Surge protection for 1-pair
  • Pluggable protection module
  • Optical fault indication
  • Remote signalling (DLAWTS1-48DC required for power supply)
  • Indirect shield connection
  • Indirect earthing
  • Signal interruption when module is disconnected
  • Conforms to IEC 61643-21, VDE 0845-3-1 and UL497B

DLA surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines. These surge protectors must be installed on symmetrical DIN rail and are available for most of the transmission lines: line voltage from 6 to 170V, bitrate up to 10 Mbit/s. These products are 1-pair surge protectors with removable module for easy maintenance.


Network

4-20mA

Nominal line voltage
Un

24 V

Max. DC operating voltage
Uc

28 Vdc

Max. frequency
f max.

3 MHz

Insertion loss

< 1 dB

Max. load current @25°C
IL

300 mA

Max. discharge current
max. withstand @ 8/20 µs by pole
Imax

20 kA

Protection mode(s)

Common/Differential mode

Protection Level
C3 (10/1000μs), 300 applications@10 A, X-X (Line/Line)
Up

40 V

Protection level
C3 (10/1000μs), 300 applications@10 A, X-C (Line/Earth)
Up

40 V

Impulse current
2 x 10/350µs Test - D1 Category
Iimp

5 kA

Nominal discharge current
C2 Category
In

5 kA

Line/Line Nominal discharge current
C2 Category
In L/L

5 kA

Nominal Discharge Current, X-C (Line/Earth)
8/20µs Test x 10 - C2 Category
In L/PE

5 kA

Line resistance (± 10%)

4.7 Ohm

Network type

Data Communication

Disconnection

Specific version with line cut-off in case of removal plug-in module

Technology

GDT+Clamping diode+PTC (thermal resistor) + Resistor

SPD configuration

1-pair+shielded

Connection to Network

Spring terminal: cross section 0.5-2.5mm²

Format

Plug-in DIN box

Mounting

Symmetrical rail 35 mm (EN 60715)

Housing material

Thermoplastic UL94 V-0

Operating temperature
Tu

-40/+85°C

Protection rating

IP20

Failsafe mode

Specific version with line cut-off in case of removal plug-in module

Disconnection indicator

Red light on

Spare module(s)

DLAWTS1M-24D3

Remote signaling of disconnection

Trough control module

Remote signaling of disconnection via control module

With attached seperated module

Connection bus

SPD connection/control module by bus: bus 1+4 (1control module+4 SPD), bus 1+9, bus 1+24 and bus 1+48

Dimensions

See diagram

Standards compliance