CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Telecom
DIN Rail Telecom/Data surge protector
DLATS-170
Stopped production - REPLACED BY: DLATS1-170 (6415051)
DLATS-170
Part Number
641405
Discover our latest innovation : the
DLAWTS1-170
1-pair dataline/telecom surge protection
Din rail mounting
Plug-in module
Local and Remote signaling of SPD status (functional/failure)
1 control module (white) + SPD modules (yellow): 24 SPDs maximum by control module
Maximum dsicharge current Imax: 20kA
Compliance with IEC/EN 61643-21,UL 497A, GB 188002.21
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DLATS is a range of pluggable dataline surge protector with remote fault signaling feature which allows the user to detect remotely a faulty surge protector. The product is made with a monitoring module which controls, through a wire bus, the status of the surge protective modules. In case of operation of an internal disconnection mechanism of the one or several surge protective modules, the monitoring module will send the information through the closing of a electrical contact. In the same time, the front LED of the defective surge protective modules, normally green color, will turn red. Thanks to the pluggable construction, the defective module will be easely replace by a new one. One monitoring module, powered by 24 Vdc, could manage up to 24 surge protective modules. The surge protective modules are based of Gas tube and fast clamping diodes association for high discharge capabilty and low clamping level. The end of lile of the SPD will create a line disconnection (Fault Mode 3 following IEC61643-21).
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Schemas
Network
Telephone line, ADSL2, SDSL
Nominal line voltage
Un
150 V
Max. DC operating voltage
Uc
170 Vdc
Max. frequency
f max.
> 10 MHz
Insertion loss
< 1 dB
Max. load current
@25°C
IL
300 mA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
20 kA
Line inductance
No
Protection mode(s)
Common/Differential mode
Protection level
@ In (8/20 µs)
Up L/L
220 V
Impulse current
2 x 10/350µs Test - D1 Category
Iimp
5 kA
Nominal discharge current
C2 Category
In
5 kA
Technology
GDT+Clamping diode
Connection to Network
By screw terminal: cross section 0.4-1.5mm² or spring terminal (DLATS-xxx/R)
Format
Plug-in DIN box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Short-circuit - transmision cut-off - fault mode 3
Voltage/operating indicator
Green / Red
Spare module(s)
DLAMTS-170
Remote signaling of disconnection
Yes
Dimensions
See diagram
Standards compliance
IEC 61643-21 / EN 61643-21 / UL497B / GBT 18802.21
Certification
×
Description:
Stopped production - REPLACED BY: DLATS1-170 (6415051)
Standards compliance:
IEC 61643-21 / EN 61643-21 / UL497B / GBT 18802.21
Certification:
EAC
Technology:
GDT+Clamping diode
Remote signaling of disconnection:
Yes
Network:
Telephone line, ADSL2, SDSL
Max. DC operating voltage:
170 Vdc
Max. discharge current :
20 kA
CITEL
Reference:
DLATS-170
Part Number:
641405
Or equivalent
Read more
About CITEL
Read more