CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DS44S-480
Type 2 AC surge protector - 3-phase+N
DS44S-480
Part Number
33101421
Type 2 AC Multipolar surge protector
In : 20 kA
Imax total : 160 kA
Pluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 compliance
UL1449 ed.5
Datasheet
ULCertificate_DS44S-480.pdf
Installation Sheet
Tender specifications
Contact Us
used mainly for primary protection of single and 4- phase networks at the main electrical panel. They provide common-mode or common and differential mode. This SPD is based on high energy varistor equipped with thermal disconnector and failure indicator, to comply with standards. The DS40 surge protectors are designed to be used in a multipolar configuration to protect single-phase, 3-phase or 3-phase+Neutral AC networks.They are sometimes associated with dedicated N/PE surge protector based on gas tube technology.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
Network
277/480 V 3-phase+N
AC system
TT-TN
Nominal line voltage
Un
480 Vac
Max. AC operating voltage
Uc
530 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
700 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
920 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
< 2 mA
Operating current
Continious current at Uc
Ic
0.5 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Connection mode(s)
L/PE and N/PE
Protection mode(s)
Common mode
Protection level N/PE
@ In (8/20µs)
Up N/PE
2.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
2.5 kV
Admissible short-circuit current
Isccr
25 000 A
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² / by bus
Format
Plug-in modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole
Spare module(s)
DSM40-480
Remote signaling of disconnection
Output on changeover contact
Weight
0.405 kg
Certification
UL
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuses type gG - 50 A
×
Description:
Type 2 AC surge protector - 3-phase+N
Certification:
UL / EAC
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
Output on changeover contact
Network:
277/480 V 3-phase+N
AC system:
TT-TN
Max. AC operating voltage :
530 Vac
Residual Current :
< 2 mA
Max. discharge current :
40 kA
Admissible short-circuit current:
25 000 A
CITEL
Reference:
DS44S-480
Part Number:
33101421
Or equivalent