CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2+3 AC surge protector
DAC1-13VG-20-150
Type 1+2+3 AC surge protector - Single phase
DAC1-13VG-20-150
Part Number
821730112
Type 1 + 2 + 3 AC surge protector
VG Technology
In : 20 kA
Iimp : 12,5 kA on 10/350µs impulse
No leakage current
Pluggable module for each phase
Remote signaling (option)
Optimized to TOV
EN 61643-11, IEC 61643-11 certified
UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DAC1-13VG is an extreme duty pluggable Type 1+2+3 SPD designed to protect AC powerline at the main switchboard of an installation equipped with lightning rod. Equipped with exclusive CITEL’s VG technology, the range achieves a high protection level, guaranteeing a maximum protection efficiency, an absence of follow and leakage currents, a simplification of use (no additional lightning protector required) and a maximum lifetime. The DAC1-13VG surge protectors are especially compact and available in multipolar versions to protect single or 3-phase AC networks, which makes them the best surge protection solution for Type 1 requirements.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2+3
Network
120 V single-phase
AC system
TN
Max. AC operating voltage
Uc
150 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
180 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
230 Vac withstand
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
100 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
25 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
6 kV
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection mode(s)
L/PE and N/PE
Protection level L/PE
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
L/PE
1.5 kV
Protection level N/PE
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
Up N/PE
1.5 kV
Protection level N/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
0.4 kV
Residual voltage L/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
0.4 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
VG Technology (MOV+GSG)
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDAC1-13VG-150
Remote signaling of disconnection
option DAC1-13VGS-20-150 : output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 2TE (EN43880)
Weight
0.282 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuse assembly: SFD1-13S-20 / or 125 A min. - 315 A max. - Fuses Type gG
×
Description:
Type 1+2+3 AC surge protector - Single phase
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
VG Technology (MOV+GSG)
SPD configuration:
Single phase
Remote signaling of disconnection:
option DAC1-13VGS-20-150 : output on changeover contact
SPD type :
1+2+3
Network:
120 V single-phase
AC system:
TN
Max. AC operating voltage :
150 Vac
Residual Current :
None
Max. discharge current :
50 kA
Total Maximum discharge current :
100 kA
Impulse current by pole :
12.5 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC1-13VG-20-150
Part Number:
821730112
Or equivalent
Read more