1-pair plug-in surge protector
Part Number: 159280
KP1-T
- Surge protector for LSA+ connection strip
- 1-pair
- Fast installation with no wiring modification
- Fast maintenance
- For analog or high speed telecom lines
These surge protectors are designed to protect telephone equipment connected to the telecom network through a MDF equipped with connection strips.
They are compatible with LSA+ connection strip.
The mechanical design allows intantaneous installation, without wiring modification, on the connection system and fast maintenance.
These products are in compliance with analog or high speed digital telecom networks.
|
Network
|
RTC, ADSL |
|
|
Nominal line voltage
|
Un | 150 Vdc |
|
Max. AC operating voltage
|
Uc | 170 Vac |
|
Max. frequency
|
f max. | > 10 MHz |
|
Insertion loss
|
< 1 dB |
|
|
Max. load current @25°C
|
IL | 300 mA |
|
Nominal discharge current
15 x 8/20 µs impulses
|
In | 5 kA |
|
Max. discharge current
max. withstand @ 8/20 µs by pole
|
Imax | 10 kA |
|
Protection mode(s)
|
Common/Differential mode |
|
|
Protection Level
C3 (10/1000μs), 300 applications@10 A, Y-Y (Line/Line)
|
Up | 230 V |
|
Protection Level
C3 (10/1000μs), 300 applications@10 A, Y-C (Line/Earth)
|
Up | 230 V |
|
Protection level L/N
@ In (8/20µs)
|
Up L/N | 230 V |
|
Protection level L/PE
@ In (8/20µs)
|
Up L/PE | 230 V |
|
Type of diagram
|
A |
|
Technology
|
GDT+TVS diode |
|
|
SPD configuration
|
1 pair |
|
|
Connection to Network
|
LSA+ connector |
|
|
Format
|
1-pair plug-in box |
|
|
Mounting
|
LSA+ connection strip |
|
|
Housing material
|
Thermoplastic UL94 V-0 |
|
|
Operating temperature
|
Tu | -40/+85°C |
|
Protection rating
|
IP20 |
|
|
Outdoor application
|
No |
|
|
Failsafe mode
|
Short-circuit - transmision cut-off - fault mode 2 |
|
|
Disconnection indicator
|
Transmision interrupt |
|
|
Remote signaling of disconnection
|
No |
|
|
Dimensions
|
See diagram |
|
Standards compliance
|
IEC 61643-21 / EN 61643-21 |