CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Photovoltaic
Type 2+3 PV surge protector
DPVN40CVG-21Y-1500
Type 2+3 PV surge protector - VG and CTC Technology
DPVN40CVG-21Y-1500
Part Number
65121103
NEW CITEL PV SPD
Type 2+3 surge protector for Photovoltaic
CTC Technology
VG Technology
Discharge currents Imax/Itotal: 40/60 kA (8/20µs)
Common/Differential mode protection
Remote signaling optional
IEC 61643-31, EN 61643-31, EN 50539-11, UL1449 ed.5 compliance
Certified EN 61643-31 and IEC 61643-31
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DPVN40VG is CITEL's new series of type 2+3 SPDs for photovoltaic applications. The development of these SPDs is based on two technologies, patented exclusively by CITEL. The VG Technology guarantees total absence of leakage current and maximum reliability. Using CTC Technology, the DPVN40VG incorporates a thermosensitive separation point placed at the center of the SPD, guaranteeing the safest disconnection on the market. The products are designed for DIN rail mounting. Compact and equipped with a fault indicator, these products are easy to install and maintain.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2+3
Network
PV 1500 Vdc
Nominal PV voltage
Uocstc
1250 Vdc
Max. PV operating voltage
Ucpv
1500 Vdc
Residual Current
Leakage current to Ground
Ipe
None
PV Permanent Operating current
Current consumption at Ucpv
Icpv
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
60 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
6 kV
Current withstand short circuit PV
Iscpv
15 000 A
Connection mode(s)
+/-/PE
Protection mode(s)
Common/Differential mode
Protection level at 5 kA
@ 5 kA (8/20µs)
Up
4,0 kV
Protection level at Uoc
@ Uoc (1.2/50 µs)
Up
3,5 kV
Technology
VG Technology (MOV+GSG)
Connection to Network
By screw terminals: 2.5-25mm² (35mm²) / by bus
Format
Compact monobloc box
Plugable
No
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
All pole disconnection from PV network
Disconnection indicator
1 mechanical indicator - Red/Green
Remote signaling of disconnection
Option DPVN40CVGS-21Y-1500 - output on changeover contact
Dimensions
See diagram - 2.5TE (EN43880)
Standards compliance
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
CTC Technology integrated
Back-up protection device
Without
×
Description:
Type 2+3 PV surge protector - VG and CTC Technology
Standards compliance:
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
VG Technology (MOV+GSG)
Remote signaling of disconnection:
Option DPVN40CVGS-21Y-1500 - output on changeover contact
SPD type :
2+3
Network:
PV 1500 Vdc
Max. PV operating voltage:
1500 Vdc
Residual Current :
None
Max. discharge current :
40 kA
Total Maximum discharge current :
60 kA
CITEL
Reference:
DPVN40CVG-21Y-1500
Part Number:
65121103