Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 (or 3) AC surge protector
DACF15-40-320
Type 2 or 3 AC surge protector - pluggable with integrated fuse
DACF15-40-320
Part Number
821310314
Type 2 (or 3) AC surge protector
Interne Disconnection device
Low caliber of the internal connector = systematic coordination with upstream circuit breaker
In : 5 kA
Imax : 15 kA
Pluggable module for each phase
Remote signaling option
EN 61643-11, IEC 61643-11, UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The special feature of this series is the integrated and monitored back-up fuse, which makes the use of an additional external back-up fuse unnecessary. Type 2 (or 3) DACF15 SPDs are used mainly for primary surge protection of single and 3-phase AC networks at the main switchboard. In addition to their thermal disconnector, the range is equipped with an internal fuse against short-circuit currents, which avoids the use of an external fuse or circuit-breaker as requested by standard. The operation of one of the both disconnectors will activate the indicator and the remote signalling (option). This compact solution simplifies the implementation and minimum space. The DACF15 surge protectors are designed to be used in a multipolar configuration to protect single-phase, 3-phase.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2 (or 3)
Network
230/400 V 3-phase+N
AC system
TNS
Max. AC operating voltage
Uc
320 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
15 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV
Protection mode(s)
L/PE and N/PE
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.2 kV
Admissible short-circuit current
Isccr
100 000 A
Technology
MOV
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDACF15-320
Remote signaling of disconnection
option DACF15S-40-320 : output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Dimensions
See diagram - 4TE (EN43880)
Weight
0.396 kg
Standards compliance
IEC 61643-11 / EN 61643-11
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
internal (equivalent AC rating : 25 A, gG Type)
Integrated fuses
Yes
×
Description:
Type 2 or 3 AC surge protector - pluggable with integrated fuse
Standards compliance:
IEC 61643-11 / EN 61643-11
Technology:
MOV
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
option DACF15S-40-320 : output on changeover contact
SPD type :
2 (or 3)
Network:
230/400 V 3-phase+N
AC system:
TNS
Max. AC operating voltage :
320 Vac
Residual Current :
< 1 mA
Max. discharge current :
15 kA
Admissible short-circuit current:
100 000 A
Integrated fuses:
Yes
CITEL
Reference:
DACF15-40-320
Part Number:
821310314
Or equivalent