CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 DC surge protector
DDC40C-20-125
DC power surge protector Type 2 - 95 Vdc
DDC40C-20-125
Part Number
828410611
Type 2 DC power surge protector
Compact design
Imax: 40 kA
Pluggable module
Remote signaling (option)
Low Up protection level
Compliance prIEC 61643-41 and UL1449 ed.5
Datasheet
Installation Sheet
Tender specifications
Contact Us
The technology based on high energy varistor equipped with thermal disconnection mechanism offers protection efficiency and and a maximal reliability. High-energy varistor technology combined with disconnectors, provides maximum protection efficiency and reliability. The Type 2 DDCC version is particularly compact and available for voltages from 12 to 350 Vdc.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
DC network 95 Vdc
Nominal PV voltage
Uocstc
95 Vdc
Max. AC operating voltage
Uc
95 Vac
Max. PV operating voltage
Ucpv
125 Vdc
Max. DC operating voltage
Uc
125 Vdc
Max. load current
@25°C
IL
20 A
Residual Current
Leakage current to Ground
Ipe
< 0.1 mA
PV Permanent Operating current
Current consumption at Ucpv
Icpv
< 0.1 mA
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Current withstand short circuit PV
Iscpv
1000 A
Connection mode(s)
+/-/PE
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
450 V
Network type
DC
Technology
MOV
Connection to Network
By screw terminals: 1.5-10mm² (actives wires) and 2.5-25mm² (ground)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Disconnection from DC network
Disconnection indicator
1 mechanical indicator - Red/Green
Spare module(s)
MDDC40C-20-125
Remote signaling of disconnection
Option DDC40CS-20-125 : output on changeover contact
Dimensions
See diagram - 1TE (EN43880)
Weight
0.118 kg
Standards compliance
prIEC 61643-41 and UL1449 ed.5
Thermal disconnector
Internal
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
DC power surge protector Type 2 - 95 Vdc
Standards compliance:
prIEC 61643-41 and UL1449 ed.5
Technology:
MOV
Remote signaling of disconnection:
Option DDC40CS-20-125 : output on changeover contact
SPD type :
2
Network:
DC network 95 Vdc
Max. AC operating voltage :
95 Vac
Max. PV operating voltage:
125 Vdc
Max. DC operating voltage:
125 Vdc
Residual Current :
< 0.1 mA
Max. discharge current :
40 kA
CITEL
Reference:
DDC40C-20-125
Part Number:
828410611
Or equivalent