CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
New Photovoltaic Range : DPVN
CTC Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Agrivoltaic
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DAC50G-10-440
Type 2 AC surge protector - 1-pole - pluggable
DAC50G-10-440
Part Number
821120411
Type 2 AC multipolar surge protector
In : 20 kA
Imax : 50 kA
Pluggable module for each phase
Remote signaling option
EN 61643-11, IEC 61643-11 compliance
UL1449 ed.5 certified
Datasheet
Installation Sheet
Tender specifications
Contact Us
The pluggable surge protectors Type 2 DAC50, are designed to protect AC powerline at the main switchboard of the installation. These SPDs are based on high energy varistor equipped with thermal disconnector and failure indicator, to comply with standards and to provide a maximum protection efficiency, a high impulse current capability and an improved reliability. The surge protectors DAC50 are available in multipolar version and in several voltages to protect single or 3-phase networks.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Max. AC operating voltage
Uc
440 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
580 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
770 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
Yes
Follow current interrupting capability
Ifi
> 100 A
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Protection level
@ In (8/20µs)
Up
1.8 kV
Residual voltage at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1.3 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
Gas discharge tube
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator
Spare module(s)
MDAC50G-440
Remote signaling of disconnection
option DAC50GS-10-440 : output on changeover contact
Dimensions
See diagram
Weight
0.088 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
OVE
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
Type 2 AC surge protector - 1-pole - pluggable
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
OVE / EAC
Technology:
Gas discharge tube
SPD configuration:
Single phase
Remote signaling of disconnection:
option DAC50GS-10-440 : output on changeover contact
SPD type :
2
Max. AC operating voltage :
440 Vac
Residual Current :
None
Max. discharge current :
50 kA
Protection level :
1.8 kV
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC50G-10-440
Part Number:
821120411
Or equivalent