2-pair plug-in surge protector
E280-12V
E280-12V
Part Number: 71142
  • 2-pair plug-in module
  • Optimized modularity and maintenance
  • Can be adapted to all types of line
  • Gas tube /diode combination
  • UL497A
Installation Sheet

The E280 concept is based on the use of plug-in module to protect telecom and data lines. The E280 line covers all multi-line telephone and data installation configurations: there is an E280 module and a suitable support for every type. Each module protects two pairs and is available for all types of line. The plug-in concept makes maintenance easy and lest you mix different types of line on the same support.



Network
RS232, RS485
Nominal line voltage
12 V
Max. DC operating voltage 15 V
Max. load current
300 mA
Max. frequency
> 3 MHz
Insertion loss
< 1 dB
Max. discharge current
max. withstand @ 8/20 µs by pole
10 kA
Total Maximal discharge current
max. total withstand @ 8/20 µs
20 kA
Line inductance
No
Protection mode(s)
Common/Differential mode
Protection level
@ In (8/20µs)
30 V
Protection level L/N
@ In (8/20µs)
30 V
Protection level L/PE
@ In (8/20µs)
30 V
Max. shunt capacitance < 500 pF
Impulse current
2 x 10/350µs Test - D1 Category
2.5 kA
Nominal discharge current
8/20µs Test x 10 - C2 Category
5 kA
Type of diagram B
 
Technology GDT+Clamping diode
SPD configuration 2 pairs
Format plug-in modul on support
Mounting on support type BN, FPSU, MMP
Housing material Thermoplastic UL94-V0
Operating temperature -40/+85°C
Protection rating IP20
Outdoor application
False
Failsafe behavior Short-circuit - transmision cut-off - fault mode 2
Disconnection indicator Transmission interrupt
Remote signaling of disconnection no
Dimensions
See diagram
Standards compliance IEC 61643-21 / EN 61643-21 / UL497 A
Certification UL listed