CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
GDT
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Wind Turbine
GDT
Accessories
LED
DIN rail LED surge protection
DLPM1-230L/15K
Surge protector for LED lighting system Class 1
DLPM1-230L/15K
Part Number:
355973
Type 2 (or 3) surge protectors for LED class I
For 230 V single-phase network
Maximum efficiency: protection level Up = 1kV
Imax: 15 kA
Mechanical status indicator
Very compact (low profile)
DIN rail mounting
Screw terminal connection
AC line Disconnection in end of life
EN 61643-11, CEI 61643-11 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DLPM range is a series of DIN-mount AC surge protector designed to be installed inside the cutouts: his compact size and lower height make it compatible with the DIN rail mounting of its enclosures. This range has a mechanical disconnect indicator.
Select another reference:
DLPM1-230L
DLPM1-230L/15K
DLPM1-230L/Y
DLPM2-230L
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2 (or 3)
Network
220-240 V Single-phase
AC system
TT-TN
Nominal line voltage
Un
230-277 Vac
Max. AC operating voltage
Uc
320 Vac
Max. load current
IL
10 A
Temporary Over Voltage (TOV) Charasteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Charasteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms disconnection
Residual Current
Leakage current to Ground
Ipe
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
15 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
20 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV / 5 kA
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
Common/Differential mode
Protection level
Following the test category C3 (IEC61643-21) - Line/Line
Up
1 kV
Protection level
Following the test category C3 (IEC61643-21) - Line/PE
Up
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV+GDT
Connection to Network
Screw terminal 2.5 mm² max. Earthing conductor 2 mm² - length 60 cm
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
LED green OFF and AC network cut-off
Voltage/operating indicator
Green Indicator
Remote signaling of disconnection
No
Dimensions
See diagram
Weight
0.073 kg
Standards compliance
EN 61643-11 / IEC 61643-11
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
×
Description:
Surge protector for LED lighting system Class 1
Standards compliance:
EN 61643-11 / IEC 61643-11
Technology:
MOV+GDT
Remote signaling of disconnection:
No
SPD type :
2 (or 3)
Network:
220-240 V Single-phase
AC system:
TT-TN
Max. AC operating voltage :
320 Vac
Residual Current :
None
Max. discharge current :
15 kA
Total Maximum discharge current :
20 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
DLPM1-230L/15K
Part Number: :
355973
Or equivalent
Read more