2-electrode GDT
BH 500/20
Part Number: 9285522
- 2-electrode GDT
- No radioactive
- In compliance with international standards
These high voltage gas tubes have been designed by CITEL on non-radioactive ceramic technology. They provide a especially high or very sparkover voltages: this allows a use on special appications as trigger circuit for discharge lamps.
This serie is available in standard version without lead (BH type) or with axial leads (BHS type).
Select another reference:
DC sparkover voltage (100V/s) | 400-600 V | |
DC spark voltage tolerance (100V/s) | +/- 20% | |
Maximum impulse sparkover voltage (1kV/µs) | <1200 V | |
Nominal discharge current | In | 20 kA |
Total Maximum discharge current | Imax Total | 40 kA |
Max. capacitance | C | <0.8 pF |
Insulation resistance | IR | ≥10 GOhms |
Arc Voltage | ≤ 25 V | |
Glow voltage | ≤ 120 V | |
AC discharge current (50Hz) | 20 A | |
DC Holdover voltage | >80 V |
Technology | Gas discharge tube | |
Operating and storage temperature | -40°C / +90°C | |
Dimensions | See diagram | |
Weight | 1.25 g |
Standards compliance | ITU-T K12 rec. | |
Certification | UL | |
RohS compliance | Yes |