CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
New Range
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
The 'Surge Protector' solution
International Standards
Citel's VG Technology
Products
Telecom
Radiocommunication
AC Power
Dataline
GDT
Miscellaneous
Photovoltaic
LED
Applications
Toggle Dropdown
Datacenter
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Services
Downloading
Webinars
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Wind Turbine
GDT
Accessories
AC Power
Type 1+2 AC surge protector
DS252E-300/G
Type 1+2 AC surge protector single-phase
DS252E-300/G
Part Number:
3404
Type 1 + 2 unipolar surge protector
Iimp total: 50 kA (10/350µs impulse)
Imax: 140 kA (8/20µs impulse)
Internal disconnections, status indicators
Remote signaling
IEC 61643-11, EN 61643-11 and UL1449 ed.4 compliance
Installation Sheet
Contact Us
The DS250E is an extreme duty Type 1+2 designed to protect the entrance of the electrical installation. They are used to protect biphase, 3-phase or 3-phase + neutral networks in common mode or in common and differential mode. The 'Multi-Varistor' technology used allows the best possible behavior for the LV network (no follow-on current). The DS250E is mounted on a DIN Rail and has a double connection for the active conductor, which allows an optimized connection to the network.
Select another reference:
DS250E-120
DS250E-300
DS250E-400
DS252E-120
DS252E-120/G
DS252E-300
DS252E-300/G
DS252E-400
DS253E-120
DS253E-300
DS253E-400
DS254E-120
DS254E-120/G
DS254E-300
DS254E-300/G
DS254E-400
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Network
230 V single-phase
AC system
TT-TN
Nominal line voltage
Un
230/400 Vac
Max. AC operating voltage
Uc
330 Vac
Max. load current
IL
100 A
Temporary Over Voltage (TOV) Charasteristics - 5 sec.
UT
335 Vac withstand
Temporary Over Voltage (TOV) Charasteristics - 120 mn
UT
440 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
UT
1200 V/300A/200 ms withstand
Residual Current
Ipe
None
Follow current
If
None
Nominal discharge current
In
70 kA
Max. discharge current
Imax
140 kA
Impulse current by pole
Iimp
25 kA
Total lightning current
Itotal
50 kA
Specific energy by pole
W/R
156 kJ/ohm
Connection mode(s)
L/N and N/PE
Protection mode(s)
Common/Differential mode
Protection level L/N
Up L/N
2.5 kV
Admissible short-circuit current
Isccr
50 000 A
Technology
MOV
SPD configuration
Single phase
Connection to Network
By screw terminals: 6-35mm² / by bus
Format
1-pole modular box assembled
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
3 mechanical indicators by pole
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.4
Certification
EAC
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Fuses
Fuse assembly: SFD1-25-11S / or Fuses Type gG 315 A